1Leading Indicators

proactive — are we doing the work?
#Measured parameter TargetActual vs last qtrAgainst targetStatus
1 Structures with a valid survey ≤ 15 months 100% 81.4% ▲ 4.2%
Off target
2 Annual inspection plan executed 95% 77.9% ▲ 6.1%
Below target
3 Rectifiers inspected within 2-month interval 100% 61% ▼ 8.4%
Off target
4 CIPS coverage of pipeline length 80% 72% ▲ 11%
Below target
5 Corrective actions closed within target date 90% 68.5% ▲ 2.4%
Off target

2Lagging Indicators

outcome — did the work protect the asset?
#Measured parameter TargetActual vs last qtrAgainst targetStatus
1 Structures unprotected 0 218 ▼ 106
Off target
2 Structures partially protected 50 431 ▼ 81
Off target
3 Rectifiers not energised 0 9 ▲ 2
Off target
4 Severe coating defects (DCVG) 10 31 ▼ 6
Off target
5 Leaks attributed to external corrosion 0 0 ● 0
On target
6 Corrective actions past due date 0 34 ▼ 12
Off target

3Risk Profile

protection state × asset criticality

One chart, five levels, twelve months — rather than five separate single-bar charts on a single date.

Risk by asset class

4Inspection Cycle

plan → survey → readings → classify → act → verify
  • 02 Mar 2026
    Annual plan issued

    FY26 inspection plan approved — 3,984 surveys scheduled across pipelines, tanks and well casings.

  • 11 Mar 2026
    Survey executed

    CIPS run on PL-06″ SGPC–TIPU, KP 0.0–16.4. Crew: A. Sattar. 412 test points walked.

  • 12 Mar 2026
    Readings captured

    ON and instant-OFF logged against Cu/CuSO₄. Depolarised survey followed 4 h after interruption.

  • 13 Mar 2026
    Classified against criterion

    −850 mV instant-OFF applied — 8 unprotected, 2 marginal, 15 protected. Worst reading −698 mV at KP 12.4.

  • 14 Mar 2026
    Corrective action raised

    Immediate: replace rectifier R-14 transformer unit. Immediate: excavate and recoat KP 12.4 holiday (34% IR).

  • 02 Apr 2026
    Action in progress

    Rectifier R-14 replaced and energised. Coating repair scheduled with the excavation crew.

  • Due 25 May 2026
    Verification re-survey

    Re-measure KP 8.0–16.4 to confirm the section returns to fully protected. Pending.