●Annual Test Post Register
state derived from instant-OFF vs −850 mV · AMPP SP0169| Test post | Structure | KP | ON (mV) | Instant-OFF (mV) | IR drop (mV) | State | Soil (Ω·cm) | Last survey | Surveyor |
|---|---|---|---|---|---|---|---|---|---|
| TP-0101 | PL-06" SGPC–TIPU | 0.40 | -1185 | -1042 | 143 | Protected | 2,400 | 2026-03-11 | A. Sattar |
| TP-0104 | PL-06" SGPC–TIPU | 4.15 | -1102 | -968 | 134 | Protected | 3,100 | 2026-03-11 | A. Sattar |
| TP-0108 | PL-06" SGPC–TIPU | 8.60 | -1046 | -894 | 152 | Protected | 4,800 | 2026-03-12 | A. Sattar |
| TP-0112 | PL-06" SGPC–TIPU | 12.40 | -905 | -698 | 207 | Unprotected | 9,600 | 2026-03-12 | A. Sattar |
| TP-0116 | PL-06" SGPC–TIPU | 16.05 | -1121 | -988 | 133 | Protected | 2,900 | 2026-03-13 | A. Sattar |
| TP-0203 | PL-10" MARI–DAHARKI | 31.20 | -1164 | -1015 | 149 | Protected | 2,200 | 2026-02-27 | M. Iqbal |
| TP-0207 | PL-10" MARI–DAHARKI | 35.80 | -1098 | -943 | 155 | Protected | 3,600 | 2026-02-27 | M. Iqbal |
| TP-0209 | PL-10" MARI–DAHARKI | 38.10 | -996 | -824 | 172 | Unprotected | 7,400 | 2026-02-28 | M. Iqbal |
| TP-0214 | PL-10" MARI–DAHARKI | 43.55 | -1142 | -1006 | 136 | Protected | 2,600 | 2026-02-28 | M. Iqbal |
| TP-0301 | PL-08" SUJAWAL Loop | 00.90 | -948 | -744 | 204 | Unprotected | 11,200 | 2026-01-19 | S. Bhatti |
| TP-0305 | PL-08" SUJAWAL Loop | 05.30 | -972 | -781 | 191 | Unprotected | 10,400 | 2026-01-19 | S. Bhatti |
| TP-0309 | PL-08" SUJAWAL Loop | 09.75 | -1058 | -902 | 156 | Protected | 5,200 | 2026-01-20 | S. Bhatti |
| TP-0402 | ZS-Flowline Network | 02.10 | -1012 | -831 | 181 | Unprotected | 6,800 | 2026-04-02 | K. Nawaz |
| TP-0406 | ZS-Flowline Network | 06.40 | -1035 | -867 | 168 | Marginal | 5,900 | 2026-04-02 | K. Nawaz |
| TP-0501 | TK-2201 Crude Storage | — | -1004 | -806 | 198 | Unprotected | 4,100 | 2026-04-18 | K. Nawaz |
| TP-0502 | TK-2202 Crude Storage | — | -1176 | -1031 | 145 | Protected | 3,800 | 2026-04-18 | K. Nawaz |
| TP-0601 | MPCL-SGPC-GRUB-WHS1 | — | -742 | -612 | 130 | Unprotected | 13,500 | 2026-02-05 | M. Iqbal |
| TP-0602 | MPCL-SGPC-GRUB-WHS2 | — | -1088 | -931 | 157 | Protected | 3,300 | 2026-02-05 | M. Iqbal |
| TP-0701 | PL-12" KANDHKOT Trunk | 02.75 | -1203 | -1074 | 129 | Protected | 1,900 | 2026-05-09 | A. Sattar |
| TP-0705 | PL-12" KANDHKOT Trunk | 07.20 | -1149 | -997 | 152 | Protected | 2,700 | 2026-05-09 | A. Sattar |
| TP-0709 | PL-12" KANDHKOT Trunk | 11.65 | -1067 | -885 | 182 | Protected | 4,600 | 2026-05-10 | A. Sattar |
| TP-0801 | PL-04" TIPU Gathering | 01.15 | -988 | -848 | 140 | Unprotected | 6,100 | 2026-03-25 | S. Bhatti |
| TP-0804 | PL-04" TIPU Gathering | 04.40 | -1024 | -871 | 153 | Marginal | 5,400 | 2026-03-25 | S. Bhatti |
| TP-0902 | PL-16" MARI Export | 18.90 | -1218 | -1096 | 122 | Protected | 1,700 | 2026-05-21 | K. Nawaz |
| TP-0907 | PL-16" MARI Export | 24.35 | -1131 | -979 | 152 | Protected | 3,000 | 2026-05-21 | K. Nawaz |