Route & Zones

a CP zone is an electrical circuit — pipe, junctions, CP devices and CP lines

Areas & zones

  • SGPCSui Gas Processing Complex 3 zones
    • Z-01 SGPC–Tipu Trunk
    • Z-02 Tipu Gathering
    • Z-03 Grub Wellheads
  • MARIMari Field 3 zones
    • Z-05 Mari–Daharki Trunk
    • Z-06 Mari Export
    • Z-07 Tank Farm 2200
  • ZSZarghun South 1 zones
    • Z-09 ZS Flowline Network
  • SJWSujawal 2 zones
    • Z-11 Sujawal Loop North
    • Z-12 Sujawal Loop South
  • KDKKandhkot 1 zones
    • Z-14 Kandhkot Trunk

Z-01  SGPC–Tipu Trunk — potential along chainage

unprotected KP 10.0–14.0
TP-0101GB-01TP-0102TP-0104TR-01TP-0106TP-0108HV crossingTP-0110DC-2201 34% IRTR-04TP-0114TP-0116
KP 0.0KP 4.1KP 8.2KP 12.3KP 16.4
Test post Rectifier Groundbed Coating defect AC interference

Zone Register

DC protection and AC interference are separate failure modes — both are reported
ZoneNameStructure kmTest posts RectifierCoating Worst inst-OFFDC stateAC risk
Z-01 SGPC–Tipu Trunk PL-06" SGPC–TIPU 16.4 16 TR-01 / TR-04 3LPE -698 mV Unprotected 18 A/m² low
Z-02 Tipu Gathering PL-04" TIPU Gathering 6.2 8 TR-07 Coal tar -848 mV Unprotected 41 A/m² elevated
Z-03 Grub Wellheads MPCL-SGPC-GRUB-WHS1/2 4 TR-14 FBE -612 mV Unprotected 6 A/m² low
Z-05 Mari–Daharki Trunk PL-10" MARI–DAHARKI 48.3 42 TR-09 / TR-11 3LPE -824 mV Unprotected 112 A/m² significant
Z-06 Mari Export PL-16" MARI Export 31.7 28 TR-27 3LPE -979 mV Protected 22 A/m² low
Z-07 Tank Farm 2200 TK-2201 / TK-2202 6 TR-29 Bitumen -806 mV Unprotected 9 A/m² low
Z-09 ZS Flowline Network ZS-Flowline Network 14.0 18 TR-16 Tape wrap -831 mV Unprotected 35 A/m² elevated
Z-11 Sujawal Loop North PL-08" SUJAWAL Loop 9.8 12 TR-18 Coal tar -781 mV Unprotected 14 A/m² low
Z-12 Sujawal Loop South PL-08" SUJAWAL Loop 7.4 10 TR-19 / TR-31 Coal tar -744 mV Unprotected 27 A/m² low
Z-14 Kandhkot Trunk PL-12" KANDHKOT Trunk 22.6 24 TR-22 / TR-24 3LPE -885 mV Protected 76 A/m² elevated

AC bands per EN ISO 18086 (supersedes EN 15280): < 30 A/m² low risk · 30–100 elevated · > 100 significant. A line can sit comfortably at −1050 mV on DC and still lose metal to AC interference near an HV crossing — Z-05 is exactly that case. Mitigation per NACE SP21424.